Li-ion battery/Polymer/LiFePO4 battery charger 3PL100-XX Series

Battery charger specifications:
NO. | ITEM | UNIT | SPECIFICATION | REMARK | |||||||
INPUT | |||||||||||
01 | Rating input voltage | V ac |
100~240V ac 50/60Hz |
||||||||
OUTPUT | |||||||||||
No. | ITEM | UNIT | Charger model | ||||||||
3PL100C-14.4 |
3PL100C-24 |
3PL100C-36 |
3PL100M-24 |
3PL100M-36 |
|||||||
02 |
Rating output voltage |
V dc | 14.4 | 29.4 | 42 | 29.4 | 42 | ||||
03 | Output voltage range | V dc |
12 ~ 15.2 |
21 ~ 29.8 |
30 ~ 42.5 |
21 ~ 29.8 |
30 ~ 42.5 |
||||
04 | Constant charge current | A |
5.0 ±0.5 |
2.8 ±0.3 |
1.8 ±0.2 |
2.8 ±0.3 |
1.8 ±0.2 |
||||
05 |
Suit with Battery type |
V/Ah |
12V LiFePO4 10~24Ah |
25.2V 10~24Ah |
36V 5.0~12A |
25.2V 10~24Ah |
36V 5.0~12A |
||||
06 | Charge finish condition | - |
>14.4V &I<0.3A |
U>29.4V I<0.3A |
U>42V &I<0.2A |
1.U>29.4V & I<0.3A 2.T/dt>=1℃/min(TYP) 3.cut-off without charging current |
1.U>42V & I<0.3A 2.T/dt>=1℃/min(TYP) 3.cut-off without charging current |
||||
07 | Max. output power | 80 | 80 | 80 | 80 | 80 | |||||
08 | Output short circuit protection | - | YES | YES | YES | YES | YES | ||||
09 |
Output Reverse polarity protection |
- | YES | YES | YES | YES | YES | ||||
10 | LED indicator | - | Red: Charging Green: Finish/idle | ||||||||
11 | Efficiency | % |
>80% |
At Max. load | |||||||
ENVIRONMENT | |||||||||||
15 |
Operate temperature |
°C |
-10 ~ +40 |
Full load & natural convection |
|||||||
16 | Operate humidity | % RH |
< +90 |
Relative humidity, non-condensing |
|||||||
17 | Storge temperature |
°C |
-40 ~ +70 | ||||||||
18 | Storge humidity | % RH | 0 ~ +95 |
Relative humidity, non-condensing |
|||||||
19 | Cooling | - | Natural convection | ||||||||
20 | Temperature factor | % | - | ||||||||
21 | Vibration resistance | - |
5MM/50HZ/600S |
Non-operating condition |
|||||||
22 | Impact resistance | - |
1 meter drop test >= 3 times |
Non-operating condition |
|||||||
MECHANICAL | |||||||||||
23 | Size | mm |
171*71*40 |
Casing only | |||||||
24 | Connect cable | - | Defined when order | ||||||||
SAFETY | |||||||||||
25 | Max. temperature rise |
°C |
< 40 on casing |
At any line and Max. load | |||||||
26 | Safety standards | - |
GB4943 UL1950 EN60950 |
||||||||
27 | EMC stand | - | EN55022 B | ||||||||
28 | MTBF | Hours | 30000 | ||||||||
29 | Limited power source | VA | 50 | ||||||||
30 | ESD | kV | 8.0 | ||||||||
31 | Hi-Pot insulation | V |
i/p to o/p: 3000 (1 min.) |
For final unit, cut-off current =10mA |